Poles Number: TypeA-SI 2P 63A 30mA

ឧបករណ៍បំបែកសៀគ្វីអេឡិចត្រូម៉ាញ៉េទិច GEYA GYL9 ប្រភេទ A-SI ពន្យាពេល RCD RCCB ELCB 40A 63A 30mA 0.03A ប្រភេទ A-SI ការពារខ្ពស់

by ដោយ GEYA

All prices exclude shipping Customs and taxes. តម្លៃទាំងអស់មិនរួមបញ្ចូលថ្លៃដឹកជញ្ជូន គយ និងពន្ធទេ។

Choose language

GEYA GYL9 A-SI Type Time Delayed RCD RCCB ELCB Electromagnetic Circuit Breaker 40A 63A 30mA 0.03A Type A-SI Super Immunised

SPECIFICATIONS

Brand Name: GEYA

Breaking Capacity: 6KA

Certification: CE

Choice: yes

Does it include a Battery?: No

Does it include wireless functionality?: No

EU LVD Voltage: Low voltage: Below 50Vac or 75Vdc

Earth-leakage Protection class: Type A-SI

Fault off Delay Time: 80~500ms

High-concerned chemical: none

Is Smart Device: no

Mechanical/Electric life: 4000times

Model Number: GYL9 A-SI Type RCCB

Mounting: Din Rail

Neutral position: Left

Origin: Mainland China

Poles: 2Pole 4Pole

Product Name: GYL9 A-SI Time Delayed RCCB/ELCB

Rated Current: 40A 63A

Rated Frequency: 50/60Hz

Rated Sensitivity: 30mA=0.03A

Rated Voltage: 220/380V

Standard: IEC61008-1

Type: Earth Leakage,Circuit breaker

Voltage: AC230/400V

is_customized: Yes

 

General

***It is TypeA-SI Time Delayed RCD RCCB ELCB 2P 4P 40A 63A 30mA0(0.03A)***
Earth-Leakage Protection Class : type A-SI (Super Immunised)

Type A RCD Features:
Tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly applied or slowly increase.
Application: loads with electronics, rectifiers, instruments.




Type SI RCD Features: 

It's designed to avoid nuisance tripping or non-tripping in case of polluted network, lightning effect, high frequency currents, RF waves, etc.
SI type RCDs present a small tripping delay (80s~500s), allowing to let pass this transient current without nuisance tripping.

In certain cases, aspects of the environment can disturb the correct operation of RCDs:
"nuisance" tripping: Break in power supply without the situation being really hazardous. This type of tripping is often repetitive, causing major inconvenience and detrimental to the quality of the user's electrical power
supply.
Non-tripping, in the event of a hazard. Less perceptible than nuisance tripping, these malfunctions must still be examined carefully since they undermine user safety.