Choose language
Brand Name: GEYA
Breaking Capacity: 6KA
Certification: CE
Choice: yes
Does it include a Battery?: No
Does it include wireless functionality?: No
EU LVD Voltage: Low voltage: Below 50Vac or 75Vdc
Earth-leakage Protection class: Type A-SI
Fault off Delay Time: 80~500ms
High-concerned chemical: none
Is Smart Device: no
Mechanical/Electric life: 4000times
Model Number: GYL9 A-SI Type RCCB
Mounting: Din Rail
Neutral position: Left
Origin: Mainland China
Poles: 2Pole 4Pole
Product Name: GYL9 A-SI Time Delayed RCCB/ELCB
Rated Current: 40A 63A
Rated Frequency: 50/60Hz
Rated Sensitivity: 30mA=0.03A
Rated Voltage: 220/380V
Standard: IEC61008-1
Type: Earth Leakage,Circuit breaker
Voltage: AC230/400V
is_customized: Yes

General
***It is TypeA-SI Time Delayed RCD RCCB ELCB 2P 4P 40A 63A 30mA0(0.03A)***
Earth-Leakage Protection Class : type A-SI (Super Immunised)
Type A RCD Features:
Tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly applied or slowly increase.
Application: loads with electronics, rectifiers, instruments.
Type SI RCD Features:
It's designed to avoid nuisance tripping or non-tripping in case of polluted network, lightning effect, high frequency currents, RF waves, etc.
SI type RCDs present a small tripping delay (80s~500s), allowing to let pass this transient current without nuisance tripping.
In certain cases, aspects of the environment can disturb the correct operation of RCDs:
"nuisance" tripping: Break in power supply without the situation being really hazardous. This type of tripping is often repetitive, causing major inconvenience and detrimental to the quality of the user's electrical power
supply.
Non-tripping, in the event of a hazard. Less perceptible than nuisance tripping, these malfunctions must still be examined carefully since they undermine user safety.