WBG833 8-Hub Controller
γFunctionγ
WBG833 wireless hub controller is suitable for controlling gas boilers, circulating pumps or electric actuators, i.e. multiple rooms independently using thermostats to control indoor temperature, with each thermostat controlling the respective branch electric heat actuators on the manifold separately to achieve independent temperature control for comfortable temperature control and reduced energy consumption.
*Hub Controller are also divided into wired and wireless, wired hubs can be click the below picture to enter:
T9W wireless wall hung gas boiler thermostat is used to control gas boiler.
*If you need to buy a full set of wireless thermostat, you can click the below picture to enter:
*Note - Up to 8pcs T9W can be connected to one WBG833
γTechnical Parametersγ
Power supply: AC100~240V; 50/60Hz
Maximum current: 10A
Storage temperature: -20~70β
Ambient humidity: -20~60β
Product size: length 280mm x width 110mm x thickness 40mm
Shell material: flame retardant PC + ABS
Max control distance: about 200m
Actuator interface: 8 normally open/normally closed electric heat actuator
Thermostat interface: 8 wireless thermostats







Electric Thermal Actuator
Description:
Electric heat actuator is mainly used in floor heating heating system to control the closing and opening of pipes. Specifically applied to the electric drive part of the electric heat actuator of the manifold branch valve, small valve, dynamic balance valve. Working operation without noise, nut connection installation method, simple, quick installation and easy disassembly.
Why choose our electric actuator?
β Compare with the 3mm on the market, our actuator stroke 4mm, spring internal expansion length can completely cover the valve spool stroke
β‘Vibration damping motor, working operation 0 noise
β’Precise internal structure, smooth action, avoiding water hammer phenomenon when the valve is opened and closed
β£Flame retardant shell, high temperature resistance and anti-aging, long service life
SpecificationοΌ
Thermal Actuator
Chinese Core, Vernet Core
Voltage: 230V
Status: NCοΌNO
Power Consumption: 2VA
Thrust: 110N
Stroke: 4mm
Running time: 3-5min
Connection size: M30*1.5mm
Ambient temperature: From -5β to 60β
Cable Length: 1000mm
The difference between NC and NO:
Most customers choose the "normally closed" type.
Normally closed: the manifold valve is normally closed, the valve is opened after the power is applied, mostly used for household wall-hung boilers sub-heating
Normally open type: manifold valve is normally open, the valve is closed after the power is applied, mostly used for engineering central heating